GENERAL DESCRIPTION
Product #3 Injection Based Injection Binder is a proprietary low viscosity, high modulus, quick strength, epoxy-based binder developed for structurally rebonding cracks, delaminations and hollow planes in Portland cement concrete. Can also be used in certain types of wood injection
For use where ever an ASTM C881-78 Type I, Grade I, Class A, B or C grade epoxy resin is required. (Under ASTM C881-88 Product #3 meets the physical requirements for both Type I, and Type IV classifications.) It is capable of penetration and performance in concrete separations 5 mils and greater. Product #3 is chemical and abrasion resistant. When used in conjunction with proper equipment, it is capable of application and performance when applied at temperatures as low as zero degrees F. #3 is insensitive to the presence of water and can be injected under water or against a hydrostatic head, when applied to temperatures above 32 degrees F.
MAJOR USES
HANDLING PROPERTIES | |
Mix Ratio | 3.5 to 1 by Volume |
Color | straw |
Mixed Viscosity (@77 Degrees F) | 275-350 CPS |
Gel Time | 12 - 15 Minutes |
Shelf Life: (@85 Degrees F Maximum Temp) | 1 Year |
Initial Cure | 24 hours |
Final Cure | 7 days |
PHYSICAL PROPERTIES | |
Elongation (ASTM D-638) | 1.6% |
Tensile Strength (ASTM D-638) | 6,970 p.s.i (Min.) |
Modulus of Elasticity (ASTM D-638) | 444,800 |
Compressive Strength (ASTM C109-75) | 12,220 |
Bond Strength, 7 days @ 77°F (AASHTO T237-73) | 7,380 |
SURFACE PREPARATION: Drilling of cracks for injection ports is best accomplished with a vacuum attached to a swivel drill chuck and hollow core drill bits. The surface of the crack and the area around the injection ports should be sealed with Epoxy.comTM Product #5, 6 or 48. Entry ports for injecting should be spaced at appropriate intervals to accomplish the full penetration of the resin. As with all injection resins, use of a plural component epoxy injection machine is the only way to insure desired results.
MIXING PROCEDURES: Supplied as two-package system. Pour Component "B" into the injection machine container labeled "B". Pour the Component "A" into the injection machine container labeled "A". Use special caution not to intermix components, or with different injection resins.
APPLICATION STEPS: Epoxy.com Product #3 should only be pumped with a positive displacement injection machine. See technical data on Concrete Injection Procedures.
HANDLING PRECAUTIONS
Prolonged or repeated exposure may cause eye and skin irritation. Avoid contact with skin or eyes. If contact occurs, wash immediately with soap and water. Flush eyes immediately with water and contact physician. If used indoors, provide adequate ventilation. Use safety glasses, and wear protective rubber or polyethylene gloves.
For more information on injection procedures , injection accessory products or other Epoxy.com Products, please contact: