CONDUCTIVE EPOXY PRIMER
Epoxy.com Product #2671
(Semi-Clear and Black)
PRODUCT DESCRIPTION
Epoxy.com Product #2671 Conductive Primer Sealer is a two component solvent based epoxy primer that exhibits excellent characteristics for abrasion resistance and static dissipative properties. Another outstanding feature for this product is the excellent substrate penetration which results in excellent adhesion characteristics. The semi-clear is a metallic pigmented primer while the black is available in a metallic pigmented version with additional lead time.
USES
Recommended for priming concrete or masonry substrates prior to applying a suitable topcoat when static control is needed.
PROPERTIES
SOLIDS BY WEIGHT: |
Clear = 61%; Black = 52% (+, - 2%) |
SOLIDS BY VOLUME: |
Clear = 51%; Black = 45% (+, - 2%) |
VOLATILE ORGANIC CONTENT: |
Mixed (Clear = <425 g/l; Black <448 g/l) |
STANDARD COLORS: |
semi-clear and black only |
REQUIRED FILM THICKNESS: |
6-7 mils per coat wet thickness (yields 3 mils dry) |
COVERAGE PER GALLON: |
229 to 267 square feet @ 6-7 mils wet thickness |
PACKAGING INFORMATION |
2 gallon and 10 gallon kits (volume approx.) |
MIX RATIO: |
1 part A to 1 part B by volume |
SHELF LIFE: |
6 months in unopened containers |
ABRASION RESISTANCE: |
Taber CS-17 wheel - 1000g total load and 500 cycles = 36.0 mg
loss |
IMPACT RESISTANCE: |
Gardner Impact, direct= 50 in. lb. (passed) |
FLEXIBILITY: |
No cracks on a 1/8" mandrel
ADHESION:
400 psi @ elcometer (concrete failure, no delamination) |
VISCOSITY: |
Mixed = clear @ 500-900 cps &
black @ 250-400 cps (typical) |
DOT CLASSIFICATION: |
"FLAMMABLE LIQUID N.O.S., 3, UN1993, PGIII" |
APPLICATION TEMPERATURE: |
40°-90° F |
TOPCOAT: |
Contact Technical Support for recommendations. |
CURE SCHEDULE: (70°F)
pot life - 1 gallon volume |
3-5 hours |
tack free (dry to touch) |
2-4 hours |
recoat or topcoat |
see limitations |
light foot traffic |
3-5 hours |
full cure (heavy traffic) |
2-7 days |
CHEMICAL RESISTANCE:
REAGENT |
RATING |
xylene |
B |
gasoline |
B |
50% sodium hydroxide |
D |
10% sulfuric |
C |
10% hydrochloric acid |
C |
20% nitric acid |
A |
ethylene glycol |
C |
Rating key: A - not recommended, B - 2 hour term splash spill, C - 8 hour term splash spill, D - 72 hour immersion, E - long term immersion. NOTE: extensive chemical resistance information is available through
Epoxy.com Technical Support. .
|
ELECTRICAL RESISTANCE: ASTM F150-89
MEASUREMENT |
RESISTANCE |
(OHMS) |
clear |
black |
LOCATION |
|
|
1. |
9.50e+4 |
9.40e+4 |
2. |
1.36e+5 |
1.80e+5 |
3. |
2.17e+5 |
1.95e+5 |
LIMITATIONS
- Colors may be affected by high humidity, chemicals, temperatures or exposure to certain types of lighting such as sodium vapor lights.
- For best results use a good quality roller.
- Slab on grade requires moisture barrier.
- Substrate temperature must be 50 F above dew point.
- All new concrete must be cured for at least 30 days.
- Product color will vary from batch to batch.
- Too thick of an application (coat) may result in product failure.
- Do not topcoat the primer until the electrical resistance is 106 ohms of resistance or lower. In some instances, it will require 24 hours to achieve proper conductivity before topcoating. (test before topcoating).
- If temperatures are below 60° F, let the material induct for 15 minutes before applying.
- This product is intended for the professional installer that has experience with this type of coating system.
- Physical properties are typical values and not specifications.
- See below for application instructions.
- See below for limitations of our liability and warranty.
MIXING AND APPLICATION INSTRUCTIONS
Product Storage
Store product in an area so as to bring the material to normal room temperature before using.
Surface Preparation
Surface preparation will vary according to the type of system to be applied. For a one or two coat thin build system (3-10 mils dry) we recommend either mechanical scarification or acid etching until a suitable profile is achieved. For a complete system build higher than 10 mils dry, we recommend a fine brush blast (shot blast). All dirt, oil, dust, foreign contaminants and laitance must be removed to assure a trouble free bond to the substrate. A test should be made to determine that the concrete is dry; this can be done by placing a 4'x4' plastic sheet on the substrate and taping down the edges. If after 24 hours, the substrate is still dry below the plastic sheet, then the substrate is dry enough to start coating.
Product Mixing
Mix equal volumes such as 1 gallon of part A to 1 gallon of part B. After the two parts are combined, mix well with slow speed mixing equipment such as a jiffy mixer until the material is thoroughly mixed and streak free. Improper mixing may result in product failure. Suitable mixing equipment may be necessary to remix in settled metallic pigment.
PRODUCT APPLICATION
The mixed material can be applied by brush or roller. Maintain temperatures within the recommended ranges during the application and curing
process. The Product #2671 conductive primer is best earthed with strips of copper about 20 centimeters long, which are anchored in the subfloor and connected to a water pipe or neutral conductor in the electric wiring system. Two earthing
points normally suffice for a single room. One earth per 200 square meters of
floor space is the general rule for large areas. After the substrate is earthed,
Apply the Product #2671 by roller or brush at the recommended (6-7 Mil) thickness. Too thick of an application may result in inefficient
conductivity or solvent entrapment that could result in product failure. Allow
sufficient time for the Product #2671 to cure before recoating. SEE ABOVE UNDER LIMITATIONS FOR TESTING PROCEDURES.
RECOAT OR TOPCOATING
Recoating is optional. If you opt to recoat or topcoat this product, you must first be sure that all of the solvents have evaporated from the coating during the curing process. Always remember that colder temperatures will require more cure time for the product before topcoating. Before topcoating, check the coating to insure no epoxy blushes were developed (a whitish, greasy film or deglossing). If a blush is present, it must be removed prior to topcoating. If topcoating
or applying multiple coats, apply the selected anti-static topcoat according
to the technical data specifications. Be sure to apply the topcoat product
at the specified coverage rate or recommended thickness. We only recommend
one coat of any anti-static topcoat be applied over the conductive sealer.
However, if multiple coats of this sealer are to be placed, then a
re-evaluation of conductive properties should be conducted at the job sight
location to determine adequate conductive properties with a representative
sample first. Consult Epoxy.com Technical Support for proper anti-static topcoat selections. Adequate leakage resistance should be less than 108 ohms measured at 500 volts per ASTM F150-89 over concrete. Typical conductive properties for this product as used on concrete with one coat is typically 105 to 109 ohms PER ASTM F150-89 at 500 volts).
Cleanup
Use xylol
Floor Cleaning
Caution! Some cleaners may affect the color of the floor installed. Test each cleaner in a small area, utilizing your cleaning technique. If no ill effects are noted, you can continue to clean with the product and process tested.
Restrictions
Restrict the use of the floor to light traffic and non-harsh chemicals until the coating is fully cured (see technical data under full cure). It is best to let the floor remain dry for the full cure cycle. Dependent on actual complete system application, surface may be slippery, especially when wet or contaminated; keep surface clean and dry.
Limitations
THIS PRODUCT IS NOT FOR A CONDUCTIVE COATING SYSTEM. THIS SYSTEM IS NOT INTENDED FOR AREAS
EXPOSED TO EXPLOSIVE MEDIA SUCH AS AMMUNITION PLANTS. THIS MATERIAL IS PROVIDED AS A STATIC
DISSIPATIVE COATING. REVIEW THE DATA ABOVE UNDER ELECTRICAL RESISTANCE FOR TESTING RESULTS.
REVIEW YOUR ELECTRICAL RESISTANTCE REQUIREMENTS BEFORE INSTALLING THIS PRODUCT. DO NOT USE WAXES
UNLESS THEY ARE SPECIFICALLY FORMULATED AND RECOMMENDED FOR ANTI STATIC APPLICATIONS. ALWAYS
APPLY TEST PATCHES OF YOUR SELECTION TO CHECK CONDUCTIVITY PRIOR TO APPLICATION AND TO BECOME
FAMILIAR WITH THE PRODUCTS APPLICATION PROCEDURE.
Notice to Buyer: Disclaimer of Warranties and Limitations on Our Liability
WARNING: Antistatic
flooring cannot provide protection against discharges from the power main.
If danger of coming in contact with the mains cannot be completely ruled
out, the usual safety regulations must be followed to the letter. Although
this publication describes how our products may be applied to achieve
antistatic flooring and the information given is based on the present state
of our knowledge, all recommendations are made without liability on our part
since the actual application of our products is not in our hands and special
conditions prevailing at a particular job sight might negatively influence a
floors antistatic properties. Buyers and users of our products should make
their own assessment of the floors antistatic properties immediately after
it has been installed and at regular intervals therafter. We warrant that
our product is manufactured to the strict quality assurance specifications
and that the information supplied by us is accurate to the best of our
knowledge. All other information supplied by us is accurate to the best of
our knowledge. Such information supplied about our products is not a
representation or a warranty. It is supplied on the condition that you shall
make your own tests to determine the suitability of our product for your
particular purpose. .
Any use or application other than recommenced herein is the sole
responsibility of the user. NO WARRANTY IS MADE, EXPRESSED OR IMPLIED,
REGARDING SUCH OTHER INFORMATION, THE DATA
ON WHICH IT IS BASED, OR THE RESULTS YOU WILL OBTAIN FROM ITS USE. N0 WARRANTY IS MADE, EXPRESSED OR IMPLIED,
THAT OUR PRODUCT SHALL BE MERCHANTABLE OR THAT OUR PRODUCT SHALL BE FIT FOR ANY PARTICULAR PURPOSE. NO WARRANTY IS MADE
THAT THE USE OF SUCH INFORMATION OR OUR PRODUCT WILL NOT INFRINGE UPON ANY
PATENT. We shall have no
liability for incidental or consequential damages, direct or indirect. Our
liability is limited to the net selling price of our product or the
replacement of our product, at our option. Acceptance of delivery of our
product means that you have accepted the terms of this warranty whether or
not purchase orders or other documents state terms that vary from this
warranty. No representative is authorized to make any representation or
warranty or assume any other liability on our behalf with any sale of our
products. Our products contain chemicals that may be CAUSE SERIOUS
PHYSICAL INJURY. BEFORE USING any material, READ THE MATERIAL SAFETY
DATA SHEET AND FOLLOW ALL
PRECAUTIONS TO PREVENT BODILY HARM.
|
Proper mixing and installation is critical to the optimal success of all products.
See
Installation Tips,
Techdata, &
MSDS for more details on our products.
Be sure to contact us with any questions and/or concerns that you have.
For more information please contact:
Epoxy.com
A Division of Epoxy Systems, Inc
A Vermont Corporation
USA
We have products that have passed the test of time as well as the best new Systems available today.
Since 1980 - 40 years of the highest quality products
Hours: 9AM-4PM Eastern Time (6AM-1PM Pacific Time)
Closed for lunch from 12Noon to 1PM
321-206-1833 Customer Service - Ordering and Order Status
Katey Lambert-Fontaine, VP - Chief Operations Officer
sales@epoxy.com
Technical Support
352-533-2167 Norm Lambert, President - Technical Support Director
info@epoxy.com
352-489-1666 Accounting and Administration
Debby Lambert, CEO, and CFO
Copyright © 1994-2023 (providing
online information about the right product for the right job for nearly 30 years) EPOXY.COM a
division of Epoxy Systems, Inc. -
Florida and Vermont. All rights reserved.
|
We accept MasterCard, Visa, American Express, Discover, or Wire Transfers.
|
|